top of page

Aeon8800A

Anaesthesia Workstation

Aeon8800A

The Aeonmed Aeon8800A is an advanced anesthesia workstation designed to provide comprehensive anesthesia care for patients of all ages. Here’s a detailed look at its features and specifications:

Key Features:

  • Ventilation Modes: The Aeon8800A supports standard ventilator-level ventilation modes suitable for various clinical situations, including volume control, pressure control, and synchronized intermittent mandatory ventilation (SIMV).

  • Eco-Optimizer: This feature precisely controls fresh gas flow to reduce gas waste, making the system more environmentally friendly.

  • Low Tidal Volume: Capable of delivering a minimum tidal volume of 10 mL, which is crucial for neonatal and pediatric patients.

  • Multi-Accessories: Includes AGSS (Anesthetic Gas Scavenging System), AGM (Anesthetic Gas Monitor), suction, and EtCO2 (End-tidal Carbon Dioxide) monitoring.

  • Lung Protection: Designed to minimize post-pulmonary complications (PPCs) by offering individualized PEEP (Positive End-Expiratory Pressure) and lung recruitment maneuvers to prevent atelectasis (lung collapse).

Physical Specifications:

  • Dimensions:
    Height: 1356 mm
    Width: 845 mm
    Depth: 620 mm

  • Weight: Approximately 110 kg (basic unit)

  • Operating Temperature: 10°C to 40°C

  • Storage Temperature: -20°C to 55°C

  • Storage Humidity: ≤93%

Ventilator Specifications:

  • Tidal Volume: 10 to 1500 mL

  • Ventilation Frequency: 2 to 100 breaths per minute

  • I:E Ratio: 4:1 to 1:8

  • PEEP: 0 to 30 cmH2O (optional)

  • Inspiratory Plateau: OFF, 5% to 60%

  • Flow Trigger: 2 to 30 L/min

  • Pressure Trigger: -20 to 0 cmH2O

  • Pressure Range: 5 to 70 cmH2O

Electrical Specifications:

  • Mains: AC 100 to 240 V, 50/60 Hz

  • Battery: DC 24 V, with a minimum of 120 minutes of operation

  • Mains Outlet: 3 outlets (1.5A each)

Gas Supply:

  • Oxygen: 0 to 1 L/min; 1 to 10 L/min

  • Nitrous Oxide: 0 to 1 L/min; 1 to 10 L/min

  • Air: 0 to 1 L/min; 1 to 12 L/min

  • Oxygen Supply Failure Protection: Ensures continuous operation in case of oxygen supply failure

  • Oxygen Flush: 25 to 75 L/min

Safety Features:

  • Safety Valve: ≤10 kPa

  • Operating Modes: Closed, Semi-closed, Semi-open

  • Driven Mode: Pneumatically driven and electronically controlled

  • Alarm Systems: Audible and visual alarms for high/low airway pressure, high/low minute volume, high/low FiO2 (when FiO2 function is enabled), power failure, oxygen supply failure, and apnea.

The Aeonmed Aeon8800A is designed to provide reliable and efficient anesthesia delivery, making it a valuable addition to any clinical setting.

Reach Medical Systems Pvt Ltd

©2025, Reach Medical Systems Private Limited

bottom of page